Multi Parameter Device MPM620

Features

  • ECG, SPo2, NIBP, Blood Glucose, Pulse rate, Temperature and Weight
  • Store patient EHR with photo on the device
  • Instant Upload EHR to Internet CLOUD
  • Wi-Fi / GSM / Bluetooth / USB connectivity

Benefits

  • Internet enabled
  • Portable & lightweight
  • Simple, easy-to-use touch-screen interface
  • Videoconferencing ready
  • IEC 610x / CE Standards compliant

Applications

  • Remote/rural health monitoring
  • Home health care
  • Ambulance & emergency transport
  • Geriatric monitoring
  • Defense & military clinics
  • Worksite & private clinics
  • Schools & childcare facilities
  • Public & commercial transport

Tech Specs

Noninvasive Blood Pressure

  • Pneumatic pressure measurement: 0~300mmHg with ±3mmHg accuracy
  • Air leakage: <2mmHg/minute @ 300mmHg with 500cc cuff volume
  • Systolic pressure range: 40~270mmHg for adult, 40~200mmHg for pediatric
  • Diastolic pressure range: 10~210mmHg for adult, 10~150mmHg for pediatric
  • MAP range: 20~230mmHg for adult, 20~165mmHg for pediatric
  • BP accuracy: mean error <= ±5mmHg with standard deviation <= 8mmHg.
  • Pulse Rate measurement: 40~240bpm with 2% or ±2bpm accuracy
  • Blood pressure measuring time: < 30sec for typical adult (80/120mmHg, 75bpm) at manual or auto mode
  • Time interval selection at auto mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes.
  • Over-pressure protection with limit of 320±10mmHg by dual transducers
  • Diastolic pressure range: 10~210mmHg for adult, 10~150mmHg for pediatric

ECG

  • Measurement range: ±0.5mVp ~ ±5mVp
  • Heart Rate range: 20~300bpm
  • Heart Rate accuracy: greater of ±2% or ±2bpm
  • Alarm delay time: <=12s
  • Input noise level for ECG amplifier: <= 30uVp-p
  • Input impedance: >= 5M ohm (single ended)
  • CMRR (common mode rejection ratio): >= 89dB
  • ECG bandwidth: 0.5~40Hz 0.05~75Hz (diagnostic mod (em) onitoring mode),

SpO2

  • Measurement range: 35% ~ 99%
  • fMroemas u7r0e%m ~en 1t 0a0c%cu racy: Arms <= 3% for SpO2 range From 70% - 100%
  • Pulse Rate measurement: 30~240bpm ±2% or ±2bpm
  • Update rate: 8 pulse beats
  • Low perfusion performance: Accuracy of SpO2 & PR remains within specified range

Respiration

  • Measurement range: 0~120rpm
  • Measurement accuracy: ±10%

Temperature

  • Measurement range: 25.0~45.0 °C
  • Measurement accuracy: ±0.2 °C
  • Response time: <= 30sec

Blood Sugar

  • Measurement range: 20~600 ml/dl
  • Blood sample requirement: 0.7μL
  • Used strip detection
  • Response time < 10sec

Body Weight

  • Measurement range: 5~180kg
  • BMI calculations
  • Measurement in Lbs and Kgs
  • Bluetooth enabled

Communication Support

  • 3G/GPRS packet data
  • WiFi (802.11 a/b/g)
  • USB connectivity to PC/Laptop