Multi Parameter Device MPM620
Features
- ECG, SPo2, NIBP, Blood Glucose, Pulse rate, Temperature and Weight
- Store patient EHR with photo on the device
- Instant Upload EHR to Internet CLOUD
- Wi-Fi / GSM / Bluetooth / USB connectivity
Benefits
- Internet enabled
- Portable & lightweight
- Simple, easy-to-use touch-screen interface
- Videoconferencing ready
- IEC 610x / CE Standards compliant
Applications
- Remote/rural health monitoring
- Home health care
- Ambulance & emergency transport
- Geriatric monitoring
- Defense & military clinics
- Worksite & private clinics
- Schools & childcare facilities
- Public & commercial transport
Noninvasive Blood Pressure
- Pneumatic pressure measurement: 0~300mmHg with ±3mmHg accuracy
- Air leakage: <2mmHg/minute @ 300mmHg with 500cc cuff volume
- Systolic pressure range: 40~270mmHg for adult, 40~200mmHg for pediatric
- Diastolic pressure range: 10~210mmHg for adult, 10~150mmHg for pediatric
- MAP range: 20~230mmHg for adult, 20~165mmHg for pediatric
- BP accuracy: mean error <= ±5mmHg with standard deviation <= 8mmHg.
- Pulse Rate measurement: 40~240bpm with 2% or ±2bpm accuracy
- Blood pressure measuring time: < 30sec for typical adult (80/120mmHg, 75bpm) at manual or auto mode
- Time interval selection at auto mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes.
- Over-pressure protection with limit of 320±10mmHg by dual transducers
- Diastolic pressure range: 10~210mmHg for adult, 10~150mmHg for pediatric
ECG
- Measurement range: ±0.5mVp ~ ±5mVp
- Heart Rate range: 20~300bpm
- Heart Rate accuracy: greater of ±2% or ±2bpm
- Alarm delay time: <=12s
- Input noise level for ECG amplifier: <= 30uVp-p
- Input impedance: >= 5M ohm (single ended)
- CMRR (common mode rejection ratio): >= 89dB
- ECG bandwidth: 0.5~40Hz 0.05~75Hz (diagnostic mod (em) onitoring mode),
SpO2
- Measurement range: 35% ~ 99%
- fMroemas u7r0e%m ~en 1t 0a0c%cu racy: Arms <= 3% for SpO2 range From 70% - 100%
- Pulse Rate measurement: 30~240bpm ±2% or ±2bpm
- Update rate: 8 pulse beats
- Low perfusion performance: Accuracy of SpO2 & PR remains within specified range
Respiration
- Measurement range: 0~120rpm
- Measurement accuracy: ±10%
Temperature
- Measurement range: 25.0~45.0 °C
- Measurement accuracy: ±0.2 °C
- Response time: <= 30sec
Blood Sugar
- Measurement range: 20~600 ml/dl
- Blood sample requirement: 0.7μL
- Used strip detection
- Response time < 10sec
Body Weight
- Measurement range: 5~180kg
- BMI calculations
- Measurement in Lbs and Kgs
- Bluetooth enabled
Communication Support
- 3G/GPRS packet data
- WiFi (802.11 a/b/g)
- USB connectivity to PC/Laptop